DAM2(CM1) series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2(CM1) circuit breaker can be mounted vertically (upright) or horizontally (transverse). DAM2(CM1) MCCB is suitable for isolation and the symbol is " ". DAM2(CM1) MCCB meets the standard: IEC60947-2 "low-voltage switchgear and control equipment

  • Product Description
  • Specifications
  • Product Features
  • More Details

Product Description

DAM2(CM1) series the rated insulation voltage of the circuit breaker is 800V,it is suitable for the distribution network of AC 50Hz / 60Hz, rated working voltage of 690V and rated current of 1250A, to distribute power and protect circuit and power equipment from being damaged caused by overload , short-circuit, under-voltage and other fault. Also for protection infrequent conversion of the circuits and infrequent start of motor and overload, short circuit, under voltage. DAM2(CM1) circuit breaker can be mounted vertically (upright) or horizontally (transverse). DAM2(CM1) MCCB is suitable for isolation and the symbol is " ". DAM2(CM1) MCCB meets the standard: IEC60947-2 "low-voltage switchgear and control equipment

Specifications

Model

Pole

Rated current (A)

Rated
operating
voltage (V)

Rated
insulation
voltage (V)

Rated ultimate short - circuit breaking capacity (Icu)

Flashover
distance(mm)

Test voltage (V)

Icu (kA)

Ics (kA)

DAM2(CM1)L-63

3

10、16、20、25、
32、40、50、63

400

500

400×1.10

25

18

0

DAM2(CM1)M-63

3、4

50

35

DAM2(CM1)L-100

3、4

16、20、25、32、40、
50、63、80、100

400

800

30

22

≤50

DAM2(CM1)M-100

2、3、4

50

35

DAM2(CM1)H-100

3

85

50

DAM2(CM1)L-100

3、4

690

10

5

DAM2(CM1)M-100

2、3、4

20

10

DAM2(CM1)L-225

3、4

100、125、140、
160、180、200、225

400

800

35

25

DAM2(CM1)M-225

2、3、4

50

35

DAM2(CM1)H-225

3

85

50

DAM2(CM1)L-225

3、4

690

10

5

DAM2(CM1)M-225

2、3、4

20

10

DAM2(CM1)L-400

3

225、250、315、
350、400

400

800

50

35

≤100

DAM2(CM1)M-400

3、4

65

42

DAM2(CM1)H-400

3

100

65

DAM2(CM1)L-400

3

690

15

8

DAM2(CM1)M-400

3、4

20

10

DAM2(CM1)L-630

3

400、500、630

400

800

50

35

DAM2(CM1)M-630

3、4

65

42

DAM2(CM1)H-630

3

100

65

DAM2(CM1)L-630

3

6910

15

8

DAM2(CM1)M-630

3、4

20

10

DAM2(CM1)M-800

3

630、700、800

400

800

75

50

DAM2(CM1)H-800

3

100

65

DAM2(CM1)M-800

3

4690

30

15

DAM2(CM1)-1250

3

800、1000、1250

400

800

85

42

DAM2(CM1)-1250

3

690

25

12.5

Rated value of the circuit break

Note: 2-poles, 4-poles circuit breakers, divided into L, M, H, they have the same breaking index as M-type.

Characteristics of inverse time breaking action of circuit breakers over-current release for power distribution when every pole is power-on at the same time

No.

Test current

I/In

Set time

Initial state

1

Conventional non-tripping current

1.05

2h(In>63A),1h(In≤63A)

Cold

2

Conventional non-tripping current

1.30

2h(In>63A),1h(In≤63A)

Immediately after Test 1

Instantaneous action characteristic setting value of the circuit breaker for distribution is 10In±20%, and instantaneous action characteristic setting value of the circuit breaker for motor protection is 12In±20%.

Characteristics of inverse time breaking action of circuit breakers over-current release for motor protection when every pole is power-on at the same time

No.

I/In

Set time

Initial state

Remark

1

1.0

>2h

Cold


2

1.2

≤2h

Immediately after Test 1


3

1.5

≤4min

Cold

10≤n≤225

≤8min

225 < in ≤ 630

4

7.2

4s≤T≤10s

Cold

10≤In≤225

6s≤T≤20s

225 < in ≤ 630

Accessories

Inverse time protection characteristic curve

Derating factors table of temperature changes

Model/Coefficient/Temperature

+40℃

+45℃

+50℃

+55℃

+60℃

DAM2(CM1)-63

1

0.94

0.88

0.80

0.72

DAM2(CM1)-100

1

0.95

0.89

0.84

0.76

DAM2(CM1)-225

1

0.96

0.91

0.87

0.82

DAM2(CM1)-400

1

0.94

0.84

0.80

0.73

DAM2(CM1)-630

1

0.93

0.88

0.83

0.76

DAM2(CM1)-800

1

0.93

0.88

0.83

0.76

DAM2(CM1)-1250

1

0.88

0.83

0.79

0.76

Model

H

H1

H2

DAM2(CM1)-63L/3P

74

89

19

DAM2(CM1)-63M/3P

82

98.5

28.5

DAM2(CM1)-63H/3P

82

98.5

28.5

DAM2(CM1)-63L/4P

-

-

-

DAM2(CM1)-63M/4P

-

-

-

DAM2(CM1)-63H/4P

-

-

-


Product Features

■ Ambient air temperature: -5℃~+40℃, and average temperature in 24h is below +35℃.
■ Altitude: The altitude of the installation site is not more than 2000m.
■ Atmospheric conditions: The air relative humidity in the highest temperature +40℃ is not more than 50%; In the low temperature can have higher relative humidity. The maximum average relative humidity is 90%, while the average monthly minimum temperature is +25℃, and consider the temperature changes in product on the surface of the gel.

Videos

Where you need an efficient solution, there you need an inquiry

Do you need a professional team to provide you with solutions? Contact us for a quote

×

Contact Us

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.

×

Inquire

*Name
*Email
*Company Name
*Tel
*Message
*Verify Code

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.