ALF-63N/H series high breaking miniature circuit breaker(MCB),conforms to IEC60898 standard, MCB has the characteristic of reliable performance, precise protective function, short release time ,and high break capacity, small volume as well, It widely used in and overload ofcontactor ,switchgear and electric apparatus.

  • Product Description
  • Specifications
  • Product Features
  • More Details

Product Description

ALF-63N/H series high breaking miniature circuit breaker(MCB),conforms to IEC60898 standard, MCB has the characteristic of reliable performance, precise protective function, short release time ,and high break capacity, small volume as well, It widely used in and overload ofcontactor ,switchgear and electric apparatus.

Specifications

Techinical Specification

ALF-63N/H Series Miniature Circuit Breaker

Standard

EN/IEC60898-1

Breaking capacity(kA)

6,10

Protection

Against overload and short circuit

Rated current(A)In

1,2,3,4,6,10,13,16,20,25,32,40,50,63

Rated voltage(V)

1PAC 230/400,240/415

1P+N,2P,3P,3P+N,4PAC400/415

Rated impulse withstand voltage Uimp(kV)

4

Rated insulation voltage Ui(V)

500

Energy limiting cass

3

Ambient temperature(℃)

-25~+40,Max.95%humidity

Thermal operating limit

1.13xln No tripping within an hour

1.45xIn Tripping within an hour

Magnertic operating

B:(3-5)xIn,C:(5-10)xIn,D:(10-20)xIn

Number of poles

1P,1P+N,2P,3P,3P+N and 4P

Type of trip

Thermal/magnetic release

Terminal capacity

16mm² flexible or 25mm² rigid up to 25A ratings

25mm²flexible or 35mm²rigid from 32A to 63A ratings

Protection degree

IP20

Installation

Mounting on 35mm DIN rail

Width

17.8mm per pole

 

 

 

Circuit breaker release characteristic

NO.

Rated current of release(A)

Initial state

Test current

Specified time

Result to be obtained

Remarks

1

1-63

cold state

1.13In

t≤1h

Non-trip


2

1-63

upon the previous test

1.45ln

t<1h

trip

Setting current up to specified value steadily in 5s

3

In≤32

cold state

2.55In

1s<t<60s 1s<t<120s

trip


In>32

4

1-63

cold state

3In

t≤0.1s

Non-trip

B type

5In

t<0.1s

trip

B type

5In 10ln

t≤0.1s

Non-trip

C type

10In

t<0.1s

trip

C type

20ln

t≤0.1s

Non-trip

D type


t<0.1s

trip

D type

 

Endurance(Operations)

Category

Operation Cycles

Operation frequency

Rated current

Electrical endurance

4000

240/h

1-32

120/h

40-63

Mechanical endurance

10000

240/h

1-63

Product Features

Features

1. Ultra-High Short-Circuit Breaking Capacity
Advanced arc control technology achieves higher interruption capacity compared to industry standards, ensuring reliable protection for industrial-grade electrical systems under extreme fault conditions.

2. Dual-Mode Connection Interface
Integrated hybrid terminal design supports both rigid busbar docking and flexible cable clamping, enabling tool-free adaptation to diverse installation scenarios while reducing wiring time by 40%.

3. Energy-Storage Mechanism for Longevity
Spring-assisted operating system with 10,000 mechanical cycles endurance , featuring wear-compensation technology

4. Advanced Composite Enclosure
with with fame-retarcant,heat-resistant, and impulse -proof properties integrated arc-quenching chambers for contained fault events.

5. Dynamic Current-Limiting Topology
Intelligent let-through energy suppression reduces peak fault currents by 65-80%, enabling downstream device specification optimization with 30% overall system cost reduction potential.

Videos

Where you need an efficient solution, there you need an inquiry

Do you need a professional team to provide you with solutions? Contact us for a quote

×

Contact Us

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.

×

Inquire

*Name
*Email
*Company Name
*Tel
*Message
*Verify Code

*We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.