DAB9-63 Miniature Circuit Breaker
DAB9-63 Miniature Circuit Breaker
DAB9-63 Miniature Circuit Breaker
Miniature Circuit Breaker
Moulded case circuit breaker
DAB9-63 Miniature Circuit Breaker
DAB9-63 Miniature Circuit Breaker
DAB9-63 Miniature Circuit Breaker
Miniature Circuit Breaker
Moulded case circuit breaker

DAB9-63 Miniature Circuit Breaker

  • Product Description
  • Specifications
  • Product Features
  • More Details

Product Description

  • Polarity: 1P, 2P, 3P, 4P;
  • Compliant with standards: IEC60898- 1/GB/T10963.1;
  • Product Function: Overload and Short Circuit Protection;
  • Certification: CE,CB,SAA; .
  • Rated current In (A):2,4, 6, 10, 16, 20, 25, 32, 40, 50, 63;
  • Rated voltage Ue: 230/240V (1P),400/415V(2P ~ 4P);
  • Rated frequency (Hz): 50/60;
  • Rated insulation voltage: 500V;
  • Rated impulse withstand voltage (Uimpact) kU: 4;
  • Rated breaking capacity Icn (kA): 6/10kA;
  • Protection level: IP20;
  • Electrical lifespan (times): 10,000;
  • Mechanical lifespan (times): 30,000;
  • Breaking ability:
  • Flame retardancy: V0 level;
  • Installation location: Any location;
  • Applicable wire cross-section; Solid wire (mm): 1-35; Twisted wire (mm2): 1-25;
  • Maximum wiring torque (N . m): 3.5;
  • Environmental temperature (C ): -25 to+45, maximum humidity of 95%;
  • Storage temperature (C):- 40~ +75;
  • Energy limit level: 3;
  • Installation altitude (meters): not exceeding 2000.

Specifications

●Tripping Characteristic Curves

IEC 60898-1

●Magnetic Release

When a circuit short circuit occurs, instantaneous tripping is achieved by a magnet with an iron core. According to the 1EC60898 standard, this product can be divided into three types: B, C, and D.

Test current Tripping time Applications
B Curve 3ln
5ln
0.1<t<45s(In ≦ 32A)
0.1<T<90s(In>32A)
Type B is only applicable to active loads:
-Electric heater-Water heater-Electric furmace
C Curve 5In
10ln
0.1<t<15s(In ≦ 32A)
0.1<T<30s(In>32A)t<0.1s
Type C is suitable for ordinary loads:
-Lamp
-Power socket
-Small power motor
D Curve 10ln
20In
0.1<t<4s(In ≦ 32A)
0.1<T<8s(ln>32A)
t<0.1s
Control and protect circuits with instantaneous surge current
(large motors)

● Thermal Release

  • Once overload occurs in the circuit, the bimetallic strip of the circuit breaker will bend due to heat, causing the contacts to disconnect and resulting in

thermal tripping;

  • The IEC standard defines the tripping time range for different overload currents;
  • The reference test environment temperature is 30 °C.
Test current Tripping time
1.13ln t z 1h(in ≦ 63A)
1.45ln t<1h(In ≦ 63A)
2.55ln 1s<1h<60s(In≤32A)1s<t<120s(In>32A)
  • Product and installation dimensions(MM)

The product is mounted on a guide rail with a maximum connection capacity of 25mm.

Product Features

●Features

  • Quick closing: ensuring reliable operation of impact loads and extending the life of circuit breakers;
  • There is a clear opening and dlosing indicator window below the handle;
  • The printed informnation on the surface of the product is long-lasting, clear, and not easy to erase;
  • The emission of ionized gases is subject to the strictest restrictions: 45mm grid distance;
  • This product complies with Type B of IEC 60898-1 standard, The characteristics of the C-type and D-type

trip curves.

Videos