DAM1L-250  Earth Leakage protection circuit breaker (ELCB)
DAM1L-250  Earth Leakage protection circuit breaker (ELCB)

DAM1L-250 Earth Leakage protection circuit breaker (ELCB)

DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.
  • Product Description
  • Specifications
  • Product Features
  • More Details

Product Description

DAM1L series residual current (leakage) circuit breaker (hereinafter referred to as circuit breaker) is a new series of residual current (leakage) successfully developed by using international standard design and advanced manufacturing technology.Protected moulded case type circuit breaker.

The rated insulation voltage of circuit breakers of this series is 400V (Inm is less than 160A) and 690V (Inm is more than 250A), which is mainly used for ac 50Hz and rated In a power distribution network with a current of 10A~500A and a rated working voltage of 380V/400V, it is used to distribute electric energy and protect the overload and short circuit of lines and power equipment.Under normal conditions,It can also be used for infrequent switching of lines.

This circuit breaker also has the following protection:

It provides protection for fire hazards caused by grounding fault current that cannot be detected due to overcurrent protection.

Provide protection against the danger of increasing ground voltage due to insulation damage;

Circuit breakers with rated residual action current not exceeding 30mA can be used for personal contact protection.

Circuit breakers with rated current of 500A and below can also be used for infrequent start, break off during operation and overload and short circuit protection of squirrel cage motors.

DAM1L series circuit breakers can be equipped with electric accessories and mechanical accessories for various purposes, such as separately excited tripping device, auxiliary contact, alarm contact and rotating handle operating mechanism.

This series of circuit breakers are widely used in construction, transportation, tunnel, residence, etc.The delay type in this series of circuit breakers is used for branch lines Distribution of roads;Adjustable type is used to adjust the residual action current or disconnection time on site.

Specifications

Residual current circuit breaker basic parameters
COSφ Rated current of remnant motion I△n

(mA)

Rated current of remnant no-motion I△no

(mA)

Max-Breaking time (S)
0.2 100,300,500 50,150,250 0.05,0.5, 0.8
Rated residual operating current(mA) Rated no tripping current value.I△no(mA) Residual current value range.(mA)0.5x(I△n+I△no)±0.2I△n
30 15mA 18mA-27mA
100 50mA 60mA-90mA
300 150mA 180mA-270mA
500 250mA 300mA-450mA
1000 500mA 600mA-900mA

 

Earth-Leakage Circuit Breakers(ELCB)
Model DAM1-125L DAM1-160L
Breaking Capacity Code B N S B N S
Rated Current of Frame size- Inm    (A) 125A 160A
Rated Current-In(40,50 or 55℃)   (A) 10 – 12,5 – 16 – 20 – 25 – 32(30) – 40 – 50 – 63(60) – 80 – 100 – 125A 10- 12,5-16-20 – 25 – 32 – 40 – 50 – 63 – 80 – 100 -125 – 160(150)A
Ui (V) 690V 690V
Ue (V) 400V 400/415V
Number of Pole 4P 4P
Icu (KA) 25 35 50 25 35 50
Ics(KA) 12.5 17.5 37.5 12.5 26.25 37.5
Icm(peak)/cos ф (KA) 40/0.3 73.5/0.25 105/0.25 41/0.3 73.5/0.25 110/0.25
(I△m)KA/cosф 9/0.5 19/0.5
Residual current threshold(mA) 100-300-500 100-300-500
Time delay(ms) 50-500-800 50-500-800
Uimp (V) 10000 8000
Dielectric Propery (V) 2500 3000
lonization distance  (mm) ≤30/0 ≤30/0
Endurance Total Cycles 8000 8000
Electrical Life 1000 1000
Mechanical Life 7000 7000
Category (EN 60947-2/IEC 60947-2) Main circuit A/0 A/0
Auxiliary circuit AC-15 AC-15
Under Voltage Release
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operastion Mechanism
Terminal cover
Phase seperator
图片8.jpg W (mm) 3P
4P 101 120
L (mm) 3P
4P 155 120
H (mm) 3P
4P 70 70
Weight Fixed version 3P/4P
Plug-in version 3P/4P
Draw out version 3P/4P
Earth-Leakage Circuit Breakers(ELCB)
Model DAM1-250L DAM1-400L
Breaking Capacity Code N S H G N S H G
Rated Current of Frame size- Inm                       (A) 250A 400A
Rated Current-In(40,50 or 55℃)                   (A) 63 – 80-100-125 – 160(180) – 200(225) – 250(320)A 250 – 315 (350)- 400 – 500A
Ui (V) 690V 690V
Ue (V) 400/415V 400/415V
Number of Pole 4P 4P
Icu (KA) 35 50 65 85 35 50 70 85
Ics(KA) 26.25 37.5 48.75 51 26.25 37.5 52.5 52.5
Icm(peak)/cos ф (KA) 77/0.25 114/0.25 143/0.2 178/0.2 70/0.25 110/0.25 154/0.2 187/0.2
(I△m)KA/cosф 12/0.3 19/0.5
Residual current threshold(mA) 100-300-500 100-300-500
Time delay(ms) 50-500-800 50-500-800
Uimp (V) 8000 8000
Dielectric Propery (V) 3000 3000
lonization distance (mm) ≤30/0※ ≤60/0※
Endurance Total Cycles 8000 5000
Electrical Life 1000 1000
Mechanical Life 7000 4000
Category (EN 60947-2/IEC 60947-2) Main circuit A/B A/B
Auxiliary circuit AC-15 AC-15
Under Voltage Release
Shunt Release
Auxiliary Contact
Alarm Contact
Auxiliary Contact and Alarm Contact
Handle Operation Mechanism
Electrical Operation Mechanism
Terminal cover
Phase seperator
图片11 W (mm) 3P
4P 140 184
L (mm) 3P
4P 210 254
H (mm) 3P
4P 103.5 103.5
Weight Fixed version 3P/4P 41.5/5.5 5.1/7.1
Plug-in version 3P/4P 4.6/6 6.5/8.5
Draw out version 3P/4P 5/6.4 6.5/8.7

 

·Icu:O-t-CO test(O:Open maneuver,CO:Close-Open maneuver,t:Waiting duration)

·Ics:O-t-CO-t-CO test(O:open maneuver,CO:Close-Open maneuver,t:Waiting duration)

 

Product Features

Range:10A to 500A(AC)

integral structure, small volume, high breaking capacity, safe and reliable.

Adjustable magnetic setting(0.8-1times)In.

Push to trip button provision.

Separate main and arcing contacts

Can be adjusted the residual action current or disconnection time according to the actual use.

Strong anti-interference ability.

Wide range of accessories.

The working power of the residual current protection circuit of this series of circuit breakers is supplied by the multi-phase power supply (the working power of the protection circuit of early products is supplied by the single-phase power supply)the residual current protection circuit of the device can still operate normally.When the operating power voltage of the circuit breaker’s residual current protection circuit is reduced to 50V, the circuit breaker’s residual current protection circuit can still work normally.(I coherence n=30mA)

This series of circuit breakers are classified into B type (i.e., basic breaking capacity) (Inm less than 100), S type (i.e., standard breaking capacity) and H type (i.e High score breaking capacity (Inm > 160) can be used in different situations.

The main circuit of a circuit breaker is connected in many ways:

Piston front connection

Terminal extension plate front connection

The screw connection at the rear of the piston plate

Videos

YouTube video