Home > Company News > How to Choose a Voltage Protector for Electrical Equipment
Voltage fluctuations can affect the reliability of electrical equipment and interrupt business operations. Selecting a suitable voltage protector requires evaluating the electrical conditions, load requirements, and protection functions needed for a specific application.
A voltage protector monitors circuit voltage and disconnects power when the measured value exceeds or falls below its configured limits. Depending on the model, it may also provide overcurrent protection and voltage and current measurement.
DADA Electric offers voltage protectors with adjustable protection settings and a configurable reconnection delay.

When the supply returns to an acceptable range, a reconnection delay can prevent equipment from restarting immediately during unstable power conditions. The appropriate setting depends on the connected load and the device specifications.
A voltage protector disconnects a circuit when voltage exceeds its configured limits, while a surge protective device limits transient overvoltage caused by lightning or electrical switching. For solar installations and other suitable DC applications, DC surge protective devices provide a separate layer of surge protection.
The rated voltage, protection thresholds, current setting, and reconnection delay must suit the supply conditions and connected equipment. DADA Electric publishes the following specifications for its voltage protector products.
| Parameter | Published specification | Selection consideration |
| Rated voltage | 220 V | Match the supply voltage |
| Frequency | 50 Hz or 60 Hz | Confirm supply compatibility |
| Overvoltage threshold | 230 V to 300 V | Check the upper protection limit |
| Undervoltage threshold | 140 V to 210 V, with another specification line stating 145 V to 210 V | Verify the specific model |
| Adjustable current setting | 1 A to 40 A or 63 A, depending on configuration | Match the load requirements |
| Reconnection delay | 1 second to 300 seconds | Consider restart requirements |
Rated current alone does not determine suitability. Consider normal operating current, startup current, operating voltage, and the protection requirements of the complete circuit. Motors and compressors may draw higher current during startup, so the selected device must be suitable for the actual load conditions.
An under voltage release can trip a compatible circuit breaker when its control voltage falls below the specified operating level. Before selecting this accessory, verify compatibility with the breaker model and control circuit.

A voltage protector and an SPD address different electrical risks. Where both sustained voltage fluctuations and transient surges are possible, the system should include suitable protection for each condition.
Unsuitable voltage thresholds may cause unnecessary disconnections or fail to provide the intended protection. Check the equipment’s permitted operating range and follow the product manufacturer’s instructions.
Some equipment should not restart immediately after a power interruption. Confirm that the available delay settings meet the requirements of the connected load.
Incorrect wiring and poor coordination between protective components can compromise electrical safety. Installation should follow the product instructions and applicable electrical codes, with work performed by qualified personnel.
Founded in 1983, Shanghai Dada Electric Co., Ltd. operates three factories with a combined production area of 52,400 square metres and more than 500 staff. Its portfolio includes over 160 products across low voltage electrical equipment and accessories.
The company reports an ISO 9001 quality management system. Buyers should verify the certifications and technical documentation applicable to the specific product model.
For further information about the company’s manufacturing background, visit the DADA Electric company profile.

A voltage protector monitors circuit voltage and disconnects power when voltage exceeds or falls below configured limits. Some models also provide current protection, measurement functions, and delayed reconnection.
Check the rated voltage, adjustable thresholds, current setting, reconnection delay, and compatibility with the connected equipment. Confirm the exact model specifications before purchase.
No. A voltage protector responds to voltage conditions outside its configured limits, while an SPD is designed to limit transient overvoltage. The appropriate protection arrangement depends on the electrical system and its risks.
Choose a voltage protector that matches your electrical supply, load, and protection requirements. For model specifications or purchasing enquiries, contact DADA Electric to discuss your needs.
Learn when to use a contactor or a control relay in industrial motor control circuits....
See More >>
Learn when to use a contactor or a control relay in industrial motor control circuits....
See More >>
Discover how a thermal overload relay protects electric motors from sustained overcurrent and overheating. This...
See More >>Do you need a professional team to provide you with solutions? Contact us for a quote
0086-15167477792
charlotte.weng@cdada.com
No.171 Yezhuang Road, Zhuanghang, Fengxian, Shanghai, China
Copyright © 2025 Shanghai DaDa Electric Co.,Ltd. All rights reserved.